| General: | |
| Operating frequency: | 433-434 MHz |
| Power output: | < 10 mW |
| Baud rate: | 9600 b/s |
| Transmission principle: | GFSK, TDMA |
| Channel Separation: | 25 kHz |
| Functional sensitivity: | ≤-107 dBm BER 10-3 |
| The radio full-fills: | R&TTE Directive 99/5EC |
| Reaction time on STOP function: | Maximum 550 ms |
| Safety category for the Stop function | ISO 13849-1 Category 3 PL d |
| Receiver RX161: | |
| 2 Separate main contactor change over safety relays | ||
| 1 Digital output for horn (siren) | 12V | |
| 1 Analogue input: | 0 (4) -20 mA or 0(2)-10 V | |
| 2 Digital inputs: | 24/48 V AC/DC (Opto-isolated) or 115/230 V AC (Opto-isolated) | |
| 1 Serial port: | RS422/RS485 | |
| Input voltage: | 24/48/115/230 V AC, power consumption less than 14 VA or 24 V DC 0.5 A. Shall be connected to SELV circuits. | |
| Dimensions: | 277x217x115 mm | |
| Weight: | Approximately 1.6 kg | |
| Degree of protection (plastic encolsure): | IP67 | |
| Operating temperature: | -25 °C - +55 °C | |
| Storage temperature: | -40 °C - +85 °C | |
| Transmitter | AQ80: | TX50: |
| Dimensions: | 181 x 65 x 43 mm | 243x77x41 (49 mm incl. quick stop) |
| Weight: | 265 g | 450 g |
| Degree of protection: | IP67 | IP65 |
| Display, Graphic LCD: | 128x64 pixels | 102*64 pixels |
| Operating Temperature for battery: | -20 °C - +55 °C | |
| Storage Temperature for battery: | -20 °C - +35 °C | |
| Charging Temperature for battery: | +10 °C - +45 °C NOTE! For charging see charger documentation |
|